The landing or floor on the exterior side shall be not more than 7 3 4 inches 196 mm below the top of the threshold provided the door does not swing over the landing or floor.
Building code exterior door landing.
Where a door opens over a landing the landing shall be at least as wide as the door and at least 5 feet long.
Where exterior landings or floors serving the required egress door are not at grade they shall be provided with access to grade by means of a ramp in.
Exterior or outdoor stair railing guardrail landing tread and step specifications codes construction requirements for safe outdoor steps stairs railings newel posts outdoor stair railing safety hazards photos of defects.
Building codes for exterior doors.
Aisle stairs complying with section 1025 11.
This handout is intended to provide only general information contact the building and safety division for any questions or additional information.
Florida building code 1009 4 stairway.
Florida building code 1009 4 stairway landings.
4 a landing may be omitted at the bottom of an exterior stair or ramp provided there is no obstruction such as a gate or door within the lesser of the width of the stair or ramp or.
Where the door opens into the stairway of a smokeproof enclosure the landing need not have a length of 5 feet.
3 1 sentence 3 does not apply to an exterior stair serving a secondary entrance to a house that is also a main entrance to a dwelling unit in the house.
When fully open the door shall not project more than 7 inches 178 mm into a landing.
Exterior doors in homes and businesses not only provide security but they also serve as a vital means of egress during a fire or other emergency.
Where exterior landings or floors serving the required egress door are not at grade they shall be provided with access to grade by means of a ramp in.
Step down on the interior and up to two steps down to the landing on the exterior regardless of which way the door swings it can only swing over one step.
The landing or floor on the exterior side shall be not more than 7 3 4 inches 196 mm below the top of the threshold provided the door does not swing over the landing or floor.
Landing requirements for all other exterior doors.
The massachusetts state building code consists of a series of international model codes and any state specific amendments adopted by the board of building regulation and standards bbrs.
Title 24 part 2 section 2 3303 i 1 and i 2 exception.
For all non egress exterior doors the 2003 code update allows a 7 3 4 in.
The bbrs regularly updates the state building codes as new information and technology becomes available and change is warranted.
R311 3 floors and landings at exterior doors there shall be a landing or floor on each side of.