R311 3 floors and landings at exterior doors.
Building code for exterior door landing.
Doors maneuvering space pull side 24 min 18 min clear at exterior doors clear at interior doors provide this additional is equipped with both a latch and a closer push side 10 min.
There shall be a landing or floor on each side of each exterior door.
Every landing shall have a minimum dimension of 36 inches measured in the direction of travel.
It also covers the size.
There shall be a landing or floor on each side of each exterior door.
Code expert glenn mathewson runs through the landing requirements for exterior doors including the threshold dimensions the number of allowable steps from the threshold down to the landing and the additional code allowances for exterior non egress doors.
The width of each landing shall not be less than the door served.
Exterior landings shall be permitted to have a slope not to exceed unit vertical in 12 units horizontal 2 percent.
This chapter provides guidelines on door height and width based on the function of the structure.
Code requirements for exterior doors are covered in chapter 10 of the ibc.
The width of each landing shall be not less than the door served.
Every home must have one egress door and it must be a specific size with a specifically dimensioned landing on both the interior and exterior side of the threshold.
The slope at exterior landings shall not exceed 1 4 unit vertical in 12 units horizontal 2 percent.
The width of each landing shall be not less than the door served.
Bottom rail 12 min front approach door construction 36 min 22 min 22 min.
The slope at exterior landings shall not exceed 1 4 unit vertical in 12 units horizontal 2 percent.