Visual and mechanical inspection 2.
Cable insulation test voltage.
The first thing to check is the cable testing environment and cable preparation.
This test recognizes the fact that good insulation will show a gradually increasing ir after the test voltage is applied.
The megger insulation tester is a small portable instrument that gives you a direct reading of insulation resistance in ohms or megohms.
The results obtained from ir test are not intended to be useful in finding localized defects in the insulation as in a true hipot test but rather give information on the quality of the bulk material used as the insulation.
If the high voltage test is made in dc it is then combined with insulation.
A high voltage cable hv cable is a cable used for electric power transmission at high voltage a cable includes a conductor and insulation cables are considered to be fully insulated.
If the cable does not pass if a cable does not pass the test the cable still may be good but additional cable evaluation should be per formed.
The reasoning is that the low energy failure of the cable under test results in less collateral damage and a reduced likelihood of unplanned outages due to in.
If the tan delta numbers indicate good cable insulation the test voltage is raised up to 1 5 2uo.
The high voltage test also called dielectric strength test or hipot test can be made in ac or dc.
Test voltage is applied to the cable while the tan delta test set takes measurements.
This means that they have a full rated insulation system which will consist of insulation semi con layers and a metallic shield.
The applied test voltage is raised in steps with measurements first taken up to 1uo or normal line to ground operating voltage.
For good insulation the resistance usually reads in the megohm range.
Comparing this result with the correct row of table 2 shows that our cable passes the insulation resistance test.
This test doesn t significantly degrade the cable.
Within those sections there are typically three main bodies of information.
If the high voltage test is made in ac it is then this is then more stressful for the sample and made according to the sketch below.
The megger insulation tester is essentially a high range resistance meter.
Expected test results section 7 consists of sections specific to each particular type of equipment.
Usually either 30 and 60 sec or 60 sec and 10 min.
Wire and cable manufacturers use the insulation resistance test to track their insulation manufacturing processes and.
The test is very sensitive to contamination in the assembly process.
Vlf tests at ieee 400 2 test levels do not damage cable systems good insulation but are used to degrade existing insulation defects to failure during the test rather than in service.
Solder flux oils mold release agents and skin oil can cause problems.
That this document list how to test specific pieces of equipment or systems.